Series
IRE

Infrared Thermometer Expanded
Laser Sighting, ±1% Accuracy, Numeric and Graphical Display

SPECIFICATIONS
Temperature Range: -25 to 1600°F (-32 to 900°C), selectable.
Accuracy: ±1% of reading or ±1.5°F (±1°C), whichever is greater.
Emissivity: adjustable from 0.1 to 1.0.
Distance-to-Target Size Ratio: 60:1, nominal.
Laser Classification: 1 mW, meets FDA Class II requirements.
Display: 4-digit.
Resolution: 0.1°F or °C.
Response Time: 250 msec.
Power Requirements: Two AA alkaline batteries (included).
Repeatability: ±0.5% of reading or ±1°F (±1°C), whichever is greater.
Thermocouple Input: Type K or J (Model IRE61-1 & IRE90 only).
Output: RS232 (Model IRE61-1 & IRE90 only).
Computer Requirements: (For Models IRE61-1 & IRE90 only): This product works with Windows® 98, Windows® 2000 or Windows® XP and one USB port.
Weight: 1.6 lb (480 g).
Agency Approvals: CE.