Accepts Type J Thermocouples, High/Low Alarm, Selectable Resolution
Measurement Range: -40 to
1400°F (-40 to 760°C), selectable. Thermocouple Input: Type J. Input Protection: 24 VDC or 24 VAC rms max input voltage on any combination
of input pins. Accuracy: ±0.1% rdg. + 2°F on -40
to 1400°F; ±0.1% rdg. +1°C on -40
to 760°C, over operating temperature
of 64 to 82°F (18 to 28°C). Output Range: -328 to 2192°F
(-210 to 1200°C). Display: 0.8" (20 mm) height, 3-1/2
digit LCD with switchable back light. Resolution: Selectable 1° or 0.1°. Reading Rate: 2.5 times/second. Ambient Operating Temperature: 32 to 122°F (0 to 50°C) max 80% RH. Storage Temperature: -4 to 140°F
(-20 to 60°C) max 70% RH. Thermocouple Connection: Standard female mini-connector. Power Requirements: 9V Alkaline
(included). Battery Life: 200 hours typical. Temperature Coefficient: 0.1 times the applicable accuracy specification
per °F from 32 to 64°F and 82 to
122°F (0 to 18°C and 28 to 50°C). Housing Material: ABS plastic. Weight: 15.5 oz (440 g). Agency Approvals: CE.