Series BV3-3A Automated Ball Valve - 3A Three-Piece SS

Electric and Pneumatic Actuators

This product is no longer available, see Series WE03 for the suggested replacement.

Specifications

Body:
3-piece.
Line Size:
1/2" to 4".
End Connections:
Tri-Clamp (liner meets BS 4825, part 3).
Pressure Limit:
1/2" to 2": 1000 psi (69 bar) WOG. 2-1/2" to 4": 800 psi (55 bar) WOG.
Wetted Materials:
Body, Ball, End Caps: CF8M stainless steel; Stem: 316 stainless steel; Seats, Body Seal, Thrust Washer, Packing: TFE.
Temperature Limit:
-40 to 450°F (-40 to 232°C) CWP.
Other Materials:
304 stainless steel, vinyl.
Agency Approvals:
Meets 3A.

ACTUATORS:
Electric:
Power Requirements:
115 VAC, 60 Hz, single phase. Optional 220 VAC, 24 VAC, 12 VDC, 24 VDC.
Power Consumption (Locked Rotor Current):
Two position: U11: 0.55A; U12 & U14: 0.75A; U15 & U17: 1.10A; U18: 2.60A; U19: 2.90A Modulating: V11: 0.55A; V12 & V14: 0.75A; V15 & V17: 1.10A; V18: 2.60A; V19: 2.90A.
Cycle Time (per 90°):
Two position: U11: 2.5 seconds; U12: 5 sec; U14: 10 sec; U15:15 sec; U17: 30 sec; U18: 12 sec; U19: 14 sec. Modulating: V11: 5 seconds; V12: 10 sec; V14: 20 sec; V15: 30 sec; V17: 60 sec; V18: 24 sec; V19: 28 sec.
Duty Cycle:
U11: 75%; U12, U14, U15, & U17: 25%; U18 & U19: 100%. Modulating: 75%.
Enclosure Rating:
NEMA 4. Optional NEMA 7.
Housing Material:
Aluminum with thermal bonding polyester powder finish.
Temperature Limit:
-40 to 150°F (-40 to 65°C).
Electrical Connection:
1/2" to 2-1/2": 1/2" NPT; 3" & 4": 3/4" NPT.
Modulating Input:
4 to 20 mA.
Standard Features:
Manual override, thermal overload protection, permanently lubricated gears, and position indicator except modulating units.

Pneumatic "DA" and "SR" Series:
Type:
DA Series is double acting and SR Series is spring return (rack and pinion).
Normal Supply Pressure:
80 psi (5.5 bar).
Maximum Supply Pressure:
120 psi (8 bar).
Air Connections:
DA1 to 5 and SR2 to 5: 1/8" female NPT; all others: 1/4" female NPT.
Air Consumption (per stroke):
DA1: 1.71 in³; DA2: 9.34 in³; DA4: 20.5 in³; DA6: 66.76 in³; DA7: 103.74 in³; SR2: 7.69 in³; SR3: 14.22 in³; SR6: 54.37 in³; SR7: 85.43 in³; SR9: 215.11 in³.
Cycle Time (90°):
DA1: .03 sec; DA2: .04 sec; DA4: .12 sec; DA6: .27 sec; DA7: .47 sec; SR2: .09 sec; SR3: .14 sec; SR6: .46 sec; SR7: .78 sec; SR9: 1.34 sec.
Housing Material:
Anodized aluminum body and epoxy coated aluminum end caps.
Temperature Limit:
-4 to 180°F (-20 to 85°C).
Accessory Mounting:
NAMUR standard.
Standard Features:
Position indicator.

Options

  • Explosion-proof Electric Actuator - Add suffix "EX" to the model number.
  • Optional Electric Actuator Supply Voltages - Contact factory for model number change.
  • Solenoid Valve - See Model SV3.

Model Chart

EXAMPLE BV3 U11 02 TC EX 3A Series BV3U1100TC-EX 1/2" 3A Three-Piece SS Automated Ball Valve, electric two position 120 VAC size 100 explosion-proof actuator, with sanitary tri-clamp.
SERIES BV3           Three-Piece Automated Ball Valve
ACTUATOR   DA1
DA2
DA4
DA5
DA6
DA7
SR2
SR3
SR6
SR7
SR9
U11
U12
U14
U15
U17
U18
U19
U21
U22
U24
U25
U27
U28
U29
U31
U32
U34
U35
U37
U38
U39
U41
U42
U44
U45
U47
U48
U49
V11
V12
V14
V15
V17
V18
V19
V21
V22
V24
V25
V27
V28
V29
V31
V32
V34
V35
V37
V38
V39
V41
V42
V44
V45
V47
V48
V49
        Direct Acting Rack & Pinion Actuator Size 32
Direct Acting Rack & Pinion Actuator Size 52
Direct Acting Rack & Pinion Actuator Size 75
Direct Acting Rack & Pinion Actuator Size 85
Direct Acting Rack & Pinion Actuator Size 100
Direct Acting Rack & Pinion Actuator Size 115
Spring Return Rack & Pinion Actuator Size 52
Spring Return Rack & Pinion Actuator Size 63
Spring Return Rack & Pinion Actuator Size 100
Spring Return Rack & Pinion Actuator Size 115
Spring Return Rack & Pinion Actuator Size 160
Electric Two Position 120 VAC Size 100
Electric Two Position 120 VAC Size 200
Electric Two Position 120 VAC Size 400
Electric Two Position 120 VAC Size 675
Electric Two Position 120 VAC Size 1500
Electric Two Position 120 VAC Size 2000
Electric Two Position 120 VAC Size 3800
Electric Two Position 220 VAC Size 100
Electric Two Position 220 VAC Size 200
Electric Two Position 220 VAC Size 400
Electric Two Position 220 VAC Size 675
Electric Two Position 220 VAC Size 1500
Electric Two Position 220 VAC Size 2000
Electric Two Position 220 VAC Size 3800
Electric Two Position 24 VAC Size 100
Electric Two Position 24 VAC Size 200
Electric Two Position 24 VAC Size 400
Electric Two Position 24 VAC Size 675
Electric Two Position 24 VAC Size 1500
Electric Two Position 24 VAC Size 2000
Electric Two Position 24 VAC Size 3800
Electric Two Position 24 VDC Size 100
Electric Two Position 24 VDC Size 200
Electric Two Position 24 VDC Size 400
Electric Two Position 24 VDC Size 675
Electric Two Position 24 VDC Size 1500
Electric Two Position 24 VDC Size 2000
Electric Two Position 24 VDC Size 3800
Electric Modulating 120 VAC Size 100
Electric Modulating 120 VAC Size 200
Electric Modulating 120 VAC Size 400
Electric Modulating 120 VAC Size 675
Electric Modulating 120 VAC Size 1500
Electric Modulating 120 VAC Size 2000
Electric Modulating 120 VAC Size 3800
Electric Modulating 220 VAC Size 100
Electric Modulating 220 VAC Size 200
Electric Modulating 220 VAC Size 400
Electric Modulating 220 VAC Size 675
Electric Modulating 220 VAC Size 1500
Electric Modulating 220 VAC Size 2000
Electric Modulating 220 VAC Size 3800
Electric Modulating 24 VAC Size 100
Electric Modulating 24 VAC Size 200
Electric Modulating 24 VAC Size 400
Electric Modulating 24 VAC Size 675
Electric Modulating 24 VAC Size 1500
Electric Modulating 24 VAC Size 2000
Electric Modulating 24 VAC Size 3800
Electric Modulating 24 VDC Size 100
Electric Modulating 24 VDC Size 200
Electric Modulating 24 VDC Size 400
Electric Modulating 24 VDC Size 675
Electric Modulating 24 VDC Size 1500
Electric Modulating 24 VDC Size 2000
Electric Modulating 24 VDC Size 3800
CONNECTION SIZE     02
03
04
06
07
08
09
10
      1/2"
3/4"
1"
1-1/2"
2"
2-1/2"
3"
4"
CONNECTION TYPE       TC   3A Sanitary Tri-Clamp
OPTIONS         EX
FO
SV
SV-A
SV-B
SV-C
SV-D
2S
  Explosion-proof Electric Actuator
Fail Open
Solenoid Valve, 120 VAC
Solenoid Valve, 12 VDC
Solenoid Valve. 24 VDC
Solenoid Valve, 240 VAC
Solenoid Valve, 24 VAC
Two Internal Auxiliary Limit Switches

 

Size
Cv
Double Acting
Pneumatic
Spring Return
Pneumatic
Two Position
Electric
Modulating
Electric
1/2"
14
BV3DA102TC-3A
BV3SR202TC-3A
BV3U1102TC-3A
BV3V1102TC-3A
3/4"
45
BV3DA203TC-3A
BV3SR303TC-3A
BV3U1203TC-3A
BV3V1203TC-3A
1"
81
BV3DA204TC-3A
BV3SR304TC-3A
BV3U1204TC-3A
BV3V1204TC-3A
1-1/2"
215
BV3DA406TC-3A
BV3SR606TC-3A
BV3U1406TC-3A
BV3V1406TC-3A
2"
410
BV3DA407TC-3A
BV3SR707TC-3A
BV3U1507TC-3A
BV3V1507TC-3A
2-1/2"
618
BV3DA608TC-3A
BV3SR908TC-3A
BV3U1708TC-3A
BV3V1708TC-3A
3"
940
BV3DA709TC-3A
BV3SR909TC-3A
BV3U1809TC-3A
BV3V1809TC-3A
4"
1840
BV3DA710TC-3A
BV3SR910TC-3A
BV3U1910TC-3A
BV3V1910TC-3A