Series SBLT2 & SBLTX Submersible Level Transmitter

Perfect for Ground Water and Wells, Lightning Protected or Intrinsically Safe

The SERIES SBLT2 & SBLTX Submersible Level Transmitters are manufactured for years of trouble free service. These series measure the height of liquid above the position in the tank referenced to atmospheric pressure. The transmitter consists of a piezoresistive sensing element, encased in a 316 SS housing.

Product Applications

  • Well monitoring
  • Ground water monitoring
  • Environmental remediation
  • Surface water monitoring
  • Down hole
  • Water Tanks

Models & Ordering

Filter By

Build Your Custom Part. Choose from SBLTX
SBLT2

Model Description Usually Ships Price Order
SBLT2-10-40
Ships: Next Day
Price: $263.00
Submersible level transmitter, range 10 psi (23.09 ft wc) [7.04 m wc], 40 ft (12.2 m) polyurethane cable. Next Day $263.00 Order
SBLT2-10-40-ETFE
Ships: Next Day
Price: $371.00
Submersible level transmitter, range 10 psi (23.09 ft wc) [7.04 m wc], 40 ft (12.2 m) ETFE cable. Next Day $371.00 Order
SBLT2-10M-18M
Ships: Next Day
Price: $293.00
Submersible level transmitter, range 10m wc, 18m polyurethane cable length. Next Day $293.00 Order
SBLT2-15-60
Ships: Next Day
Price: $293.00
Submersible level transmitter, range 15 psi (34.63 ft wc) [10.56 m wc], 60 ft (18.3 m) polyurethane cable. Next Day $293.00 Order
SBLT2-15-60-ETFE
Ships: Next Day
Price: $455.00
Submersible level transmitter, range 15 psi (34.63 ft wc) [10.56 m wc], 60 ft (18.3 m) ETFE cable. Next Day $455.00 Order
SBLT2-20-60
Ships: Next Day
Price: $293.00
Submersible level transmitter, range 20 psi (46.18 ft wc) [14.08 m wc], 60 ft (18.3 m) polyurethane cable. Next Day $293.00 Order
SBLT2-20-60-ETFE
Ships: Next Day
Price: $455.00
Submersible level transmitter, range 20 psi (46.18 ft wc) [14.08 m wc], 60 ft (18.3 m) ETFE cable. Next Day $455.00 Order
SBLT2-3.5M-5M
Ships: Next Day
Price: $228.50
Submersible level transmitter, range 3.5m wc, 5m polyurethane cable length. Next Day $228.50 Order
SBLT2-5-40
Ships: Next Day
Price: $263.00
Submersible level transmitter, range 5 psi (11.54 ft wc) [3.52 m wc], 40 ft (12.2 m) polyurethane cable. Next Day $263.00 Order
SBLT2-5-40-ETFE
Ships: Next Day
Price: $371.00
Submersible level transmitter, range 5 psi (11.54 ft wc) [3.52 m wc], 40 ft (12.2 m) ETFE cable. Next Day $371.00 Order
SBLT2-5M-10M
Ships: Next Day
Price: $252.50
Submersible level transmitter, range 5m wc, 10m polyurethane cable length. Next Day $252.50 Order

Can't find what you need? Build Your Custom Part. Choose from SBLTX
SBLT2

Specifications

Service:
Compatible liquids.
Wetted Materials:
316 SS, 316L SS, Epoxy; Cable: Polyurethane or ETFE; Bullet Nose: PVC.
Accuracy:
±0.25% FS.
Temperature Limit:
SBLT2: 0 to 150°F (-18 to 66°C); SBLTX: 0 to 176°F (-18 to 80°C).
Compensated Temperature Range:
SBLT2: 0 to 140°F (-18 to 60°C); SBLTX: 0 to 176°F (-18 to 80°C).
Thermal Effect:
±0.02% full scale/°F.
Pressure Limit:
2X FS.
Power Requirement:
SBLT2: 10 to 30 VDC (≤1000 ft (305 m) of cable); SBLTX: 10 to 28 VDC.
Output Signal:
4 to 20 mA DC, 2-wire.
Response Time:
50 ms.
Max. Loop Resistance:
900 Ω at 30 VDC.
Electrical Connections:
Wire pigtail.
Mounting Orientation:
Suspended in tank below level being measured.
Electrical Protection:
SBLT2: Lightning and surge protection; SBLTX: None.
Weight:
2.2 lb (1.0 kg).
Agency Approvals:
SBLT2: CE; SBLTX: CE, cULus intrinsically safe for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III Div. 1. (According to control drawing 01-700797-00). *Only up to 196 ft (59.5 m) for ETFE cable and 333 ft (101.5 m) for polyurethane cable.

Features

  • Slim design for tight applications with bullet nose design which protects the diaphragm from damage
  • Incorporates lightning and surge protection utilizing dual arrestor technology, grounded to case, eliminating both power supply surges and lightning ground strike transients (surge protection is not guaranteed and is not covered by warranty) on SBLT2 models
  • Maintenance free filter eliminates particulate or water droplets from entering the transducer
  • UL approved intrinsically safe on SBLTX models for use in hazardous locations when used with proper barrier
  • Excellent chemical compatibility
  • 270 lb tensile strength shielded and vented cable
  • NPT connection allows the unit to be rigidly installed in a pipe/conduit, or the addition of a A-625 hanging loop for attaching a chain for pulling out of the installation
  • Standard 72 hour lead time ensures minimal downtime

Options

  • -Intrinsically Safe Approval - Change model number from SBLT2 to SBLTX.
  • -Custom Ranges or Cable Lengths.

Accessories

Model Number Description Usually Ships Price Order
Intrinsically safe zener barrier. MTL7706 Intrinsically safe zener barrier. Next Day $418.00 Order
Dessicant Vent Filter for submersible level transmitters A-297 Dessicant Vent Filter for submersible level transmitters Next Day $19.00 Order
Lift Loop/Hanger for submersible level transmitters A-625 Lift Loop/Hanger for submersible level transmitters Next Day $25.00 Order
Galvanic barrier MTL5541 Galvanic barrier Next Day $790.00 Order

Videos

Model Chart


     DWYER INSTRUMENTS, INC.                  CONFIGURATOR HELP FILE
     SBLT2 SUBMERSIBLE LEVEL TRANSMITTER      LAST REVISED: 12-08-16

 
     SBLT2-XX-XX-OPT      SBLT2 SUBMERSIBLE LEVEL TRANSMITTER
         
          1ST SYMBOL (1ST X) SENSOR (DECIMALS ALLOWED)
             ?     RANGE
                   3-400 PSI OR 2.2-280 METERS
                   RANGES < 3.552 PSI OR 2.5 METERS (1%)
                    
          2ND SYMBOL (2ND X) SENSOR UNITS
                   SENSOR RANGE IN PSI IF BLANK
             M     SENSOR RANGE IN METERS
                    
          3RD SYMBOL (3RD X) CABLE LENGTH
             ?     10-2000 FT OR 3-600 METERS
                    
          4TH SYMBOL (4TH X) CABLE UNITS (WHOLE NUMBERS ONLY)
                   CABLE LENGTH IN FEET IF BLANK
             M     CABLE LENGTH IN METERS
 
          OPTIONS (OPT) KITS
            -ETFE  ETFE CABLE  (STD IS POLYURETHANE)
            -P1    1/4 IN NPTM (STD IS 7/16-14)
            -P2    1/4 IN NPTF
            -P3    1/4 INBSPT MALE ISO 228 R
            -P4    1/4 INBSPT FEMALE ISO 228 RC



       DWYER INSTRUMENTS, INC.                  CONFIGURATOR HELP FILE
     SBLTX SUBMERSIBLE LEVEL TRANSMITTER      LAST REVISED: 11-28-16

 
     SBLTX-XX-XX-OPT      SBLTX SUBMERSIBLE LEVEL TRANSMITTER
         
          1ST SYMBOL (1ST X) SENSOR RANGE (DECIMALS ALLOWED)
             ?     RANGE
                   3-400 PSI OR 2.2-280 METERS
                   RANGES < 3.552 PSI OR 2.5 METERS (1%)
                    
          2ND SYMBOL (2ND X) SENSOR UNITS
                   SENSOR RANGE IN PSI IF BLANK
             M     SENSOR RANGE IN METERS
                    
          2RD SYMBOL (3RD X) CABLE LENGTH
             ?     10-195 FT ETFE   OR 10-330 FT PU
                   3-59 METERS ETFE OR 3-100 METERS PU
                    
          4TH SYMBOL (4TH X) CABLE UNITS (WHOLE NUMBERS ONLY)
                   CABLE LENGTH IN FEET IF BLANK
             M     CABLE LENGTH IN METERS
 
          OPTIONS (OPT) KITS
            -ETFE  ETFE CABLE  (STD IS POLYURETHANE)
            -P1    1/4 IN NPTM (STD IS 7/16-14)
            -P2    1/4 IN NPTF
            -P3    1/4 IN BSPT MALE ISO 228 R
            -P4    1/4 IN BSPT FEMALE ISO 228 RC
            -2YR   2 YEAR WARRANTY



 

Product Literature

Manuals

Catalog Pages

Product Data Sheet

Approvals

Drawings

Questions

Question
Is it safe to soak an MBLT level transmitter in vinegar or muratic acid to remove accumulated scale deposits?
Answer
Feel free to use whatever cleaning chemicals you like to remove accumulated scale deposits as long as the chemicals are compatible with the unit’s wetted materials as specified in our published literature.
Question
Our client has an MBLT pressure transmitter that appears to be malfunctioning due to scale buildup. The transmitter is installed to measure leachate level in a one-year old municipal sanitary landfill. What can we use to remove scale from the transmitter without damaging the transmitter?
Answer
If the issue is due to build-up which consequently plugs the small sensing holes, you might take a look at our PBLT2 or FBLT series. They are both more rugged and designed for sludge and slurries, whereas the MBLT and SBLT2 are better suited for cleaner applications such as ground water and wells.

Photo Downloads