Series LTC2 Tilt Switch Control Unit

Adjustable Time-Delay

The Series LTC2 Tilt Probe Control Units feature an adjustable time delay and a logic selector switch. The logic selector switch determines when the output relay actuates and de-actuates, thus while in position one, the relay is energized when the probe is in the vertical position and de-energizes when the probe is in the titled position, and while in position two, the actions are opposite. In addition, an adjustable time-delay feature may be assigned to either the vertical or the tilt position to prevent false signals. The relay assumes the de-energized position upon reaching the end of the delay period as well as upon failure of power to the controller.

Product Applications

  • Large hoppers
  • Silos
  • Crushers
  • Trippers
  • Stackers
  • Conveyors

Models & Ordering

Model Description Usually Ships Price Code Order
LTC2
Ships: Next Day
Price: $842.00
Tilt switch control unit, NEMA 4 enclosure. Next Day $842.00 B Order

Specifications

Temperature Limit:
-4 to 104°F (-20 to 40°C).
Power Requirements:
115 VAC @ 50/60 Hz.
Power Consumption:
10W.
Switch Type:
DPDT.
Electrical Rating:
5 A @ 120 VAC; 5 A @ 240 VAC.
Enclosure:
Cast aluminum.
Enclosure Rating:
None or NEMA 4, 4X.
Electrical Connections:
No suffix: 120 VAC; B suffix: 240 VAC.
Conduit Connections:
3/4 NPT: 2 power/relay & 1 probe.
Indicator Light :
Green (when relay is energized and probe vertical); Red (when relay is de-energized and probe tilted), LED lamps.
Time Delay:
0.1 to 35 sec; Adjustment will delay output relay action.

Features

  • Adjustable time delay feature may be assigned to either the vertical or the tilt position to prevent false signals
  • Logic selector switch determines when the output relay actuates and deactuates, thus while in position one, the relay is energized when the probe is in the vertical position and de-energizes when the probe is in the titled position, and while in position two, the actions are opposite
  • Relay assumes the de-energized position upon reaching the end of the delay period as well as upon failure of power to the controller

Product Literature

Manuals

Catalog Pages

Drawings

Photo Downloads

You must be logged in to view this content.