Series 3100D Explosion-proof Differential Pressure Transmitter

Series 3100D Explosion-proof Differential Pressure Transmitter

Series 677B Differential Pressure Transmitter

Series 677B Differential Pressure Transmitter

Series 616KD Differential Pressure Transmitter

One-Touch® Digital Push-Button Calibration Technology, ±0.25, ±1, or ±2% Accuracy

The Series 616KD Differential Pressure Transmitters with One-Touch® Digital Push- Button Calibration Technology are designed for simplicity, making them the ideal choice for installers and maintenance professionals. These instruments not only alleviate cumbersome turn pots typically found in most transmitters, but eliminate entirely the need to span the instruments during calibration. With a single digital push button, both ZERO AND SPAN are calibrated properly, nothing else is required. No additional reference pressure sources or separate calibration devices are necessary.

NIST CALIBRATION available in Product Configurator.

**For additional ranges, see Series 616KD-LR Differential Pressure Transmitter - Low Ranges.

Product Applications

  • Air handlers
  • Duct pressure
  • Variable air volume
  • Filter monitoring
Starting at $93.10
Filter By
Grouped product items
Model Description Availability* Qty Price
616KD-00 Differential pressure transmitter, 0 to 1" w.c., 4-20 mA. 1-3 days*
$93.10
616KD-00-V Differential pressure transmitter, 0 to 1" w.c., selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-01 Differential pressure transmitter, 0 to 2" w.c., 4-20 mA. 1-3 days*
$93.10
616KD-01-V Differential pressure transmitter, 0 to 2" w.c., selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-02 Differential pressure transmitter, 0 to 3" w.c., 4-20 mA. 1-3 days*
$93.10
616KD-02-V Differential pressure transmitter, 0 to 3" w.c., selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-03 Differential pressure transmitter, 0 to 5" w.c., 4-20 mA. 1-3 days*
$93.10
616KD-03-V Differential pressure transmitter, 0 to 5" w.c., selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-04 Differential pressure transmitter, 0 to 10" w.c., 4-20 mA. 1-3 days*
$93.10
616KD-04-V Differential pressure transmitter, 0 to 10" w.c., selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-05 Differential pressure transmitter, 0 to 15" w.c., 4-20 mA. 1-3 days*
$93.10
616KD-05-V Differential pressure transmitter, 0 to 15" w.c., selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-06 Differential pressure transmitter, 0 to 20" w.c., 4-20 mA. 1-3 days*
$93.10
616KD-06-V Differential pressure transmitter, 0 to 20" w.c., selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-07 Differential pressure transmitter, 0 to 25" w.c., 4-20 mA. 1-3 days*
$93.10
616KD-07-V Differential pressure transmitter, 0 to 25" w.c., selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-10 Differential pressure transmitter, 0 to 250 Pa, 4-20 mA. 1-3 days*
$93.10
616KD-10-V Differential pressure transmitter, 0 to 250 Pa, selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-11 Differential pressure transmitter, 0 to 500 Pa, 4-20 mA. 1-3 days*
$93.10
616KD-11-V Differential pressure transmitter, 0 to 500 Pa, selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-12 Differential pressure transmitter, 0 to 750 Pa, 4-20 mA. 1-3 days*
$93.10
616KD-53 Differential pressure transmitter, 10-0-10" w.c., 4-20 mA. 1-2 Weeks*
$93.10
616KD-53-V Differential pressure transmitter, 10-0-10" w.c., selectable 0 to 10 / 0 to 5 volt output. Less Than 1 Week*
$93.10
616KD-08 Differential pressure transmitter, 0 to 40" w.c., 4-20 mA. 1-2 Weeks*
$93.10
616KD-08-V Differential pressure transmitter, 0 to 40" w.c., selectable 0 to 10 / 0 to 5 volt output. Less Than 1 Week*
$93.10
616KD-12-V Differential pressure transmitter, 0 to 750 Pa, selectable 0 to 10 / 0 to 5 volt output. Less Than 1 Week*
$93.10
616KD-13 Differential pressure transmitter, 0 to 1250 Pa, 4-20 mA. 1-3 days*
$93.10
616KD-13-V Differential pressure transmitter, 0 to 1250 Pa, selectable 0 to 10 / 0 to 5 volt output. 1-3 days*
$93.10
616KD-14 Differential pressure transmitter, 0 to 2500 Pa, 4-20 mA. 1-3 days*
$93.10
616KD-15 Differential pressure transmitter, 0 to 5000 Pa, 4-20 mA. 1-3 days*
$93.10
616KD-A-02 Differential pressure transmitter, 0-3" w.c., +/- 0.25% FS, 4-20 mA 1-2 Weeks*
$170.55
616KD-A-02-V Differential pressure transmitter, 0-3" w.c., +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-A-03 Differential pressure transmitter, 0-5" w.c., +/- 0.25% FS, 4-20 mA 1-2 Weeks*
$170.55
616KD-A-03-V Differential pressure transmitter, 0-5" w.c., +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-A-04 Differential pressure transmitter, 0-10" w.c., +/- 0.25% FS, 4-20 mA 1-2 Weeks*
$170.55
616KD-A-04-V Differential pressure transmitter, 0-10" w.c., +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-A-05 Differential pressure transmitter, 0-15" w.c., +/- 0.25% FS, 4-20 mA 1-2 Weeks*
$170.55
616KD-A-05-V Differential pressure transmitter, 0-15" w.c., +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-A-06 Differential pressure transmitter, 0-20" w.c., +/- 0.25% FS, 4-20 mA 1-2 Weeks*
$170.55
616KD-A-06-V Differential pressure transmitter, 0-20" w.c., +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-A-07 Differential pressure transmitter, 0-25" w.c., +/- 0.25% FS, 4-20 mA 1-2 Weeks*
$170.55
616KD-A-07-V Differential pressure transmitter, 0-25" w.c., +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-A-08 Differential pressure transmitter, 0-40" w.c., +/- 0.25% FS, 4-20 mA 1-3 days*
$170.55
616KD-A-08-V Differential pressure transmitter, 0-40" w.c., +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-A-12 Differential pressure transmitter, 0-750 Pa, +/- 0.25% FS, 4-20 mA 1-2 Weeks*
$170.55
616KD-A-12-V Differential pressure transmitter, 0-750 Pa, +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-A-13 Differential pressure transmitter, 0-1250 Pa, +/- 0.25% FS, 4-20 mA 1-2 Weeks*
$170.55
616KD-A-13-V Differential pressure transmitter, 0-1250 Pa, +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-A-14 Differential pressure transmitter, 0-2500 Pa, +/- 0.25% FS, 4-20 mA 1-2 Weeks*
$170.55
616KD-A-14-V Differential pressure transmitter, 0-2500 Pa, +/- 0.25% FS, voltage 1-2 Weeks*
$170.55
616KD-B-00 Differential pressure transmitter, 0-1" w.c., +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-00-V Differential pressure transmitter, 0-1" w.c., +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-01 Differential pressure transmitter, 0-2" w.c., +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-01-V Differential pressure transmitter, 0-2" w.c., +/- 1.0% FS, voltage 1-3 days*
$108.15
616KD-B-02 Differential pressure transmitter, 0-3" w.c., +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-02-V Differential pressure transmitter, 0-3" w.c., +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-03-V Differential pressure transmitter, 0-5" w.c., +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-03 Differential pressure transmitter, 0-5" w.c., +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-04 Differential pressure transmitter, 0-10" w.c., +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-04-V Differential pressure transmitter, 0-10" w.c., +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-05 Differential pressure transmitter, 0-15" w.c., +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-05-V Differential pressure transmitter, 0-15" w.c., +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-06 Differential pressure transmitter, 0-20" w.c., +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-06-V Differential pressure transmitter, 0-20" w.c., +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-07 Differential pressure transmitter, 0-25" w.c., +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-07-V Differential pressure transmitter, 0-25" w.c., +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-08 Differential pressure transmitter, 0-40" w.c., +/- 1.0% FS, 4-20 mA 1-3 days*
$108.15
616KD-B-08-V Differential pressure transmitter, 0-40" w.c., +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-10 Differential pressure transmitter, 0-250 Pa, +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-10-V Differential pressure transmitter, 0-250 Pa, +/- 1.0% FS, voltage Call for Details*
$108.15
616KD-B-11 Differential pressure transmitter, 0-500 Pa, +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-11-V Differential pressure transmitter, 0-500 Pa, +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-12 Differential pressure transmitter, 0-750 Pa, +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-12-V Differential pressure transmitter, 0-750 Pa, +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-13 Differential pressure transmitter, 0-1250 Pa, +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-13-V Differential pressure transmitter, 0-1250 Pa, +/- 1.0% FS, voltage 1-2 Weeks*
$108.15
616KD-B-14 Differential pressure transmitter, 0-2500 Pa, +/- 1.0% FS, 4-20 mA 1-2 Weeks*
$108.15
616KD-B-14-V Differential pressure transmitter, 0-2500 Pa, +/- 1.0% FS, voltage 1-2 Weeks*
$108.15

Specifications

Service:
Air and non-combustible, compatible gases.
Wetted Materials:
Consult factory.
Accuracy:
616KD-A: ±0.25% FS; 616KD-B: ±1% FS, 616KD: ±2% FS.
Stability:
±1% FS/year.
Temperature Limits:
0 to 140°F (-17.8 to 60°C).
Compensated Temperature Range:
20 to 122°F (-6.67 to 50°C).
Pressure Limits:
2 psig (ranges 5" w.c. or lower); 5 psig (ranges 10 to 40" w.c.).
Thermal Effect:
616KD-A: ±0.02% FS/°F; 616KD-B: ±0.04% FS/°F; 616KD: ±0.06% FS/°F, includes zero and span.
Power Requirements:
4-20 mA output: 10 - 35 VDC (2 wire) or 12-26 VAC (4 wire); 5V output: 10 - 35 VDC (3 wire) or 12-26 VAC (4 wire); 10V output: 13 - 35 VDC (3 wire) or 12-26 VAC (4 wire) for 616KD A and B. 16 to 36 VDC (2 or 3 wire): 20 to 28 VAC (3 wire) for 616KD.
Output Signal:
4 to 20 mA or option with field selectable 0 to 10, 0 to 5, 2 to 10, 1 to 5 V.
Zero and Span Adjustments:
Push button.
Loop Resistance:
4 to 20 mA output (DC): 0 to 1250 Ω max. Rmax = 50(VpsDC -10) Ω; 4 to 20 mA output (AC): 0 to 1200 Ω max. Rmax = 50(1.4 VpsAC -12) Ω; Voltage output: 5 KΩ minimum.
Current Consumption:
24 mA max for 616KD A and B. 21 mA max for 616KD.
Electrical Connections:
Screw-type terminal block.
Process Connections:
Barbed, dual size to fit 1/8" & 3/16" (3 mm and 5 mm) ID rubber or vinyl tubing.
Enclosure Rating:
NEMA 1 (IP20).
Mounting Orientation:
Vertical with pressure connections pointing down.
Weight:
1.8 oz (51 g).
Agency Approval:
CE, UL Standard 2043.

Features

  • Simple calibration push-button sets back zero and span, saving time installing and over the service life
  • Cost effective and compact device suitable for OEM applications where space, simplicity, and value are key
  • Ranges and accuracy selection cover a wide range of applications minimizing components and determining standardizing on design
  • Optional 1/8" NPT process connection allows for use with metal barbed fittings or compression fittings for use with metal tubing

Model Chart

EXAMPLE616KDA00ATSeries 616KD-A-00-AT, Differential Pressure Transmitter, 4-20mA, range 0-1" w.c., with aluminum tag
SERIES616KD   Differential Pressure Transmitter
ACCURACY  A
B
C
  0.25% FS Accuracy
1.0% FS Accuracy
2.0% FS Accuracy (TBD)
RANGE  00
01
02
03
04
05
06
07
08
10
11
12
13
14
15
50
51
57
52
53
54
55
56
58
 0-1" w.c.
0-2" w.c.
0-3" w.c.
0-5" w.c.
0-10" w.c.
0-15" w.c.
0-20" w.c.
0-25" w.c.
0-40" w.c.
0-250 Pa
0-500 Pa  
0-750 Pa  
0-1250 Pa  
0-2500 Pa  
0-5000 Pa  
0 to ±1" w.c.
0 to ±2" w.c.
0 to ±3" w.c.
0 to ±5" w.c.
0 to ±10" w.c.
0 to ±250 Pa
0 to ±500 Pa
0 to ±750 Pa
0 to ±1250 Pa
OPTIONS   AT
COC
FC
N
NIST
TC
V
Z1
Z2
Aluminum Tag
Certificate of Conformance
Factory Calibration
NPT
NIST Certification (A & B only)
Terminal Cover
Voltage output 0 to 5, 1 to 5, 0 to 10, 2 to 10 VDC (field select)
+/- 1%FS Zero-Deadband (Only with -A/B/C)
+/- 2%FS Zero-Deadband (Only with -A/B/C)
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
Model Description Availability* Price
A-302F-A 303 SS Static pressure tip with mounting flange, for 3/16" I.D. rubber or plastic tubing. 4" insertion depth, includes mounting screws 1-3 days*
$12.40
A-360 Aluminum DIN rail - only available in 1 m length (2.8 ft). 1-3 days*
$11.35
A-480 Plastic static pressure tip 1-3 days*
$2.15
A-489 4" 303 SS straight static pressure tip with flange, 1/4" hose barb. 1-3 days*
$9.50
A-618 Protective terminal cap 1-3 days*
$1.95
SCD-PS 100 to 240 VAC/VDC to 24 VDC power supply 1-3 days*
$40.75