Series LCI132 Process Indicator

1/32 DIN, Fully Programmable

THE SERIES LCI132 PROCESS INDICATORS offer flexibility and value in a low cost, compact 1/32 DIN package. The shallow depth of these full size panel meters allows installation in panels only 2.76" (70 mm) deep with room to spare.

Product Applications

  • Display process values from various transmitters

Models & Ordering

Model Description Usually Ships Price Order
LCI132-00
Ships: Consult Factory
Price: $209.00
Process indicator, ±100 VDC; ±20 VDC; ±10 VDC; ±200 VDC; ±20 mA DC input, 120/240 VAC supply voltage. Consult Factory $209.00 Order
LCI132-01
Ships: Same Day
Price: $209.00
Process Indicator, ±100 VDC; ±20 VDC; ±10 VDC; ±200 VDC; ±20 mA DC input, 24/48 VAC supply voltage. Same Day $209.00 Order
LCI132-10
Ships: Same Day
Price: $209.00
Process Indicator, ±100 VAC; 600 VAC; 5A (DC) 1A (DC); -199.9 to +600 VDC; ±100 VDC; -1.999 to 5A (DC) ±1A (DC) input, 120/240 VAC supply voltage. Same Day $209.00 Order
LCI132-11
Ships: Consult Factory
Price: $209.00
Process Indicator, ±100 VAC; 600 VAC; 5A (DC) 1A (DC); -199.9 to +600 VDC; ±100 VDC; -1.999 to 5A (DC) ±1A (DC) input, 24/48 supply voltage. Consult Factory $209.00 Order

Specifications

LCI132-0X
Range:
Input Volts (DC): ±200 V, ±20 V, ±10 V; Input Amperes: ±100 mV, ±20 mA;
Resolution:
Input Volts (DC): 0.1 V, 0.01 V, 1 mV; Input Amperes: 0.1 mV, 0.01 mA; Input Impedance: Volts: 1 M Ω, mV: 100 M Ω, mA: 12.1 Ω.
LCI132-1X
Range AC:
Input Volts: 600.0, 100.0; Input Amperes: 5.000, 1.000;
Range DC:
Input Volts: -199.9, ±600.0, ±100.0; Input Amperes: -1.999, +5.000, ±1.000;
Resolution:
Input Volts: 0.1 V; Input Amperes: 1 mA Input Impedance: Volts: 3 M Ω (106), Amps: 12 m Ω (10-3).
Accuracy at 23ºC ±5ºC:
100/600 VDC 1/5 A DC; 600V/5A AC: ±(0.2% reading + 3 digits). 100 V / 1A AC: ±(0.4% reading + 4 digits).
Temperature Coefficient:
100 ppm/°C.
Warm Up:
5 minutes.
Power Supply and Fuses (DIN 41661) (Not supplied)
LCI132-X0:
85–265 VAC 50/60 Hz and 100-300 VDC: Fuse: 0.1A/ 250V.
LCI132-X1:
21-53 VAC 50/60Hz and 10.5-70 VDC: Fuse 0.5A/ 250V.
Display
LCI132-X0:
85–265 VAC 50/60 Hz and 100-300 VDC: Fuse: 0.1A/ 250V.
LCI132-X1:
21-53 VAC 50/60Hz and 10.5-70 VDC: Fuse 0.5A/ 250V.
Environmental
Operating Temperature:
-10 to 60°C.
Storage Temperature:
-25 to 85°C.
Relative Humidity (non condensed):
< 95% @ 40°C.
Panel Sealing:
NEMA 4X (IP66).

Features

  • Fits in 1/32 DIN panel cutouts
  • IP65 (NEMA 4X) front housing
  • Fully programmable
  • Various voltage and current inputs fits most processes

Product Literature

Catalog Pages

Drawings

Photo Downloads

You must be logged in to view this content.