Thermocouple Input, User Configurable, 12-Bit Resolution
No. of Channels: Eight; one for internal thermistor and seven
for external T/C inputs. Internal Thermistor Range: -40 to 158°F (-40 to 70°C). Memory Size: 1,048,000 readings. Accuracy: ±1% of full scale. Clock Accuracy: ±8 seconds per day plus one sampling
interval. Resolution: 12 bits. Sampling Methods: Continuous (first-in, first-out) or stop
when full (fill-then-stop). Sampling Rates: Selectable from 0.04 seconds to once every 8
hours. Ambient Operating Temperature/RH: -50 to 160°F (-45 to 70°C),
0 to 95% RH, non-condensing. Connection: Removable screw terminal. Computer Requirements: IBM compatible running
Windows® 3.1,
Windows® 95, Windows® 98, Windows® 2000, Windows® ME,
Windows® NT, or Windows® XP. Power Requirements: Built-in 3.6V Lithium battery. Housing Material: Plastic. Weight: 5 oz (110 g). Agency Approvals: CE.