Series 1207 Handheld Flue Gas Analyzer

RS232 Output, Stores 150 Readings, 11 Pre-Programmed Fuels

This product is no longer available, please email: Tech Support for a replacement product.

Specifications

Ranges:
O2: 0-21%; CO: 0-4000 ppm; CO2: 0-99.9%; NO: 0 to 5000 ppm; Temp. (Flue and nett): 32-1112°F (0-600°C); Efficiency: 0-99.9%; Poison Index: 0-99.9%; Excess Air: 0-2885%.
Accuracy:
O2: ±0.2%; CO: ±20 ppm <400 ppm, ±5% >400 ppm; CO2: ±0.3% of rdg.; NO: ±5 ppm <100 ppm, ±5% >100 ppm; Temp.: ±5°F (±2°C), 0.3% of rdg.; Efficiency: ±1.0% of rdg.; Poison Index: ±0.01; Excess Air: ±0.2%.
Resolution:
O2: 0.1%; CO: 1 ppm; CO2: 0.1%; NO: 1 ppm; Temp.: 1.0°F/C; Efficiency and Excess Air: 0.1%; Poison Index; 0.01%.
Ambient Operating Temperature:
32 to 104°F (0 to 40°C).
Power:
110 VAC adapter (220 VAC optional).
Computer Requirements:
IBM compatible 386 or above and Windows® 3.1 or later with 2MB RAM and 2MB hard drive disk space, one serial port.
Pre-Programmed Fuels:
Natural gas, Town gas, Light oil, Heavy Oil, Coke, Coal, Anthracite, Propane, Butane, Kinsale gas, and Gascor.
Probe:
11-1/4" (28.6 cm) length, stainless steel, Type K thermocouple, 9 ft (3 m) neoprene hose.
Weight:
2.2 lb (1 kg).
Agency Approvals:
CE.