Product Configurator - Series 123/125 Boiler Water Level Control

Model Number: (- Required Selection)
X-X
Model
123 123 Single Stage, Automatic Reset, Brass Trim, Nema 1
123XLW 123 Replacement Float, Cap, and Switch Assembly Only, No Chamber for 123
123WP 123 Single Stage, Automatic Reset, Brass Trim, Weatherproof Housing
123RU 123 Single Stage, Manual Reset, Brass Trim, NEMA 1
123RUSST 123 Single Stage, Manual Reset, SST Trim, NEMA 1
123RL 123 Single Stage, Manual Reset, Brass Trim, NEMA 1
123RLSST 123 Single Stage, Manual Reset, SST Trim, NEMA 1
123RUXLW 123 Replacement Float, Cap, and Switch Assembly Only, No Chamber for 123RU
123RLXLW 123 Replacement Float, Cap, and Switch Assembly Only, No Chamber for 123RL
123SST 123 Single Stage, Automatic Reset, SST Trim, NEMA 1
123XLS 123 Replacement Switch Assembly Only, for 123
123SSTWP 123 Single Stage, Automatic Reset, SST Trim, Weatherproof Housing
125 125 Two Stage, Automatic Reset, Brass Trim, NEMA 1
125XLW 125 Replacement Float, Cap, and Switch Assembly Only, No Chamber for 125
125WP 125 Two Stage, Automatic Reset, Brass Trim, Weatherproof Housing
125SST 125 Two Stage, Automatic Reset, SST Trim, NEMA 1
125XLS 125 Replacement Switch Asembly Only for 125
125SSTWP 125 Two Stage, Automatic Reset, SST Trim, Weatherproof Housing
Circuits
2 9-51 NC SPST Mercury Switch
3 9-51 NO SPST Mercury Switch
103 (2) 9-51 NO DPST Mercury Switch
127 (2) 9-51 NO DPST Mercury Switch
151V (2) 9-35 (4-wire) SPST Vibration Damped Mercury Switch
152 9-62 (4-wire) SPST Mercury Switch
153 9-64 (3-wire) SPDT Mercury Switch
156 (2) 9-51 (4-wire) SPST Mercury Switch
160 9-61 NO SPST & 9-51 NC (4-wire) SPST Mercury Switch
162 9-51 NO (4-Wire) SPST & 9-61 NC SPST Mercury Switch
702 9-51 NO SPST & 9-64 (3-wire) SPDT Mercury Switch
705 9-51 NO SPST & 9-64 (3-wire) SPDT Mercury Switch
729 9-64 (3-wire) SPDT Mercury Switch
804 (2) 9-64 DPDT Mercury Switch
7000-153 SPDT Snap Switch
4806 (2) 9-64 6-wire DPDT Mercury Switch
4810 9-64 3-wire SPDT Mercury Switch
4814 (2) 9-51 NO DPST Mercury Switch
4815 (2) 9-51 4-wire SPDT Mercury Switch
4820 9-51 NC SPST Mercury Switch
4821 9-51 NO SPST Mercury Switch
4822 Consult Factory For Details
4823 2 Stage Control, (2) 9-51 Mercury Switches
4828 (2) 9-35AV 4-wire SPDT Mercury Switch
4829 Consult Factory For Details
4831 2 Stage Control, (2) 9-51 NO SPST Mercury Switches
4849 2 Stage Control, (2) 9-51 NO SPST Mercury Switches
4853 2 Stage Control, (2) 9-64 3-wire SPDT & (1) 9-51 NO SPST
4855 2 Stage Control, (2) 9-64: 3-wire SPDT & (1) 9-51 NC SPST
4857 Consult Factory For Details
5820 9-51 NC SPST Mercury Switch, 440VAC-rated
5821 9-51 NO SPST Mercury Switch 440VAC-rated
5822 Consult Factory For Details
5823 2 stage control, (2) 9-51 Mercury Switches
5831 2 Stage Control, (2) 9-51 NO SPST Mercury Switches
5849 2 Stage Control, (2) 9-51 Mercury Switches
Options
-STW SS Tag Wired
-23720 Fungus Proofing Spec 23720
-440V 440 Volt Options for Circuits
Model Number & Pricing Incomplete
Lead Time: 10 Days
List Price: $0.00
Net Options: $0.00