Inputs: FIV: (Field Selectable) Analog: 4-20 mA, 0-20 mA, 0-5 V, 1-5 V, 0-10 V, 1-10V. FIP: (Field Selectable) Pulse: Pulse or Square Wave 0-5 V or 0-12 V @ 30 kHz max.; TTL; Open Collector 4.7 KΩ pull-up to 12 V @ 30 kHz; Switch Contact 4.7 KΩ pull-up to 12 V @ 40 Hz. Display: 6 digit, 7 segment 0.56" (14.2 mm) high;
Rate: -19,999(0) to 29,999(0) with selectable extra zero;
Total: 0 to 999,999; automatic lead zero blanking. Accuracy: ±0.1% F.S., ±0.004 mA. Supply Voltage: 115 or 230 VAC ±10%, 50/60 Hz. Power Consumption: 12 VA. Enclosure: 1/8 DIN, high impact plastic. Operating Temperature: 32 to 140ºF (0 to 60ºC). Alarm Points: 0 or 2. Alarm Output Relay Ratings: 2 SPDT (form C), rated 2 A @ 30
VDC or 2 A @ 250 VAC resistive, 1/14 hp @ 125/250 VAC for
inductive. Alarm Point Deadband: 0 to 100% of full scale, user selectable. Isolation: FIV: 500 VDC or peak AC, input-to-output or input/output-to-power line. FIP: 1500 VAC. Loop Power Supply: Isolated 24 VDC ±5% @ 20 mA, regulated.
Maximum loop resistance is 1200Ω. Weight: 16 oz (454 g). Front Panel Rating: NEMA 4X, Panel gasket provided.