For Water and Water Based Liquids/Oil and Oil-Based Liquids
Service: Water and water based liquids/oil and oil-based
liquids. Wetted Materials: Sensor Head: 303 SS. Low Flow Set Point: Auto set @ 50% / Adjustable via "set" push button. Set Point Range: 5.0 ft/sec (0-150 cm/sec.) Repeatability: < 0.5%. Hysteresis: 10% of set-point value typical. Medium Temperature Limits: -4 to 176°F (-20 to 80°C.) Pressure: 450 psi (30 bar). Response Time: 25 seconds (typical). Supply Voltage: 20-30 VDC (short circuit protected). Switching Current: < 200 mA. Power Consumption: 6 W max. Electrical Connection: M12 male socket 4pin +2m cable
with M12 connector and pigtail. Process Connection: 1/2" Male NPT Thread. Enclosure Rating: IP 65 (NEMA 4). Initial Operation: After 15 seconds. Switch Type: PNP N.O. (switch closed with flow), PNP
N.C. (switch open with flow). Weight: .55 lb (.25 kg).