Service: Clean liquids that pass ultrasound and do not contain air bubbles (such
as pure water and chemical solution). Turbidity: 10000 deg (mg/L) or less. Type of Flow: Well-developed turbulent or laminar flow in a fluid-filled pipe. Permissible Air Volume Rate: Up to 2% at 1 m/s (inversely proportional to
velocity). Range: 0 to ± 32.8 fps (0 to ±10 m/s). Flow Pipe Sizes: SX3A: 0.98 to 3.94 in (25 to 100 mm) for plastic piping 1.97
to 3.94 in (50 to 100 mm) for metal piping; SX3B: 1.97 to 8.86 in (50 to 225 mm);
SX3C: 1.97 to 11.81 in (50 to 300 mm); SX3D: 11.81 to 23.62 in (300 to
600 mm). Accuracy: 1.5 to 2% of rate. Response Time: System cycle: 0.2s, Dead time: 0.2s or less, Time constant:
0.1s. Temperature Limits: Ambient -4 to 140°F (-20 to 60°C). Fluid Temperature:
SX3A/SX3B: -4 to 212°F (-20 to 100°C); SX3C/SX3D w/ silicone rubber for
acoustic couplant: -4 to 176°F (-20 to 80°C), w/ silicone free grease for acoustic
couplant: 32 to 140°F (0 to 60°C). Enclosure Rating: SX3A and SX3B: IP65 (Jetproof) when using waterproof
BNC connector. SX3C and SX3D: IP67 (Immersion-proof) when the terminal
block is filled with silicone rubber after wiring. Materials: For SX3A and SX3B: Plastic PBT for sensor housing, 304SS for
guide frame. For SX3C and SX3D: Plastic PBT for sensor housing, 304SS for
sensor cover, 304SS and PBT for guide rail. Electrical Connection: Coaxial cable up to 98.4 ft (30 m) and thermal stability
of 212°F (100°C). Mounting: Clamped on pipe surface. Weight: SX3A: 10.6 oz (0.3 kg), SX3B: 14.1 oz (0.4 kg), SX3C: 2.2 lb (1 kg), SX3D: 14.1 oz (0.4 kg).