Compressed Air Meters
Steady-State and Cumulative Totals PNP/4-20 mA Output
Service:
Compressed air; Air quality (see chart on Catalog Page).
Wetted Materials:
Stainless Steel (304S15), ceramics, glass passivated, PEEK, polyester, Fluoroelastomer, anodized aluminum.
Accuracy:
Class 141: ±3% of measured value + 0.3% of full scale value; Class 344: ±6% of measured value + 0.6% of full scale value.
Response Time:
< 0.1 seconds.
Temperature Limit:
32 to 140°F (0 to 60°C).
Pressure Limit:
232 psig (16 bar).
Humidity Limit:
90% RH.
Power Requirements:
19-30 DC.
Output Signal:
Output 1: PNP Open Collector: VOUT(max)=30 VDC/ISINK(max)= 250mA; Output 2: 4-20 mA (scaleable) or PNP Open Collector.
Loop Resistance:
500 ohms.
Current Consumption:
<100 mA.
Electrical Connections:
4 pin M12 (Micro) Cable Connection.
Process Connections:
1/2˝, 1˝ and 2˝ NPT.
Display:
4-digit alpha numeric red LED.
Enclosure Rating:
IP 65 (NEMA 4X).
Mounting Orientation:
Vertical, Horizontal, Side with pipe length facing left.
Weight:
CAM-10: 12.5 lb; CAM-20: 2.35 lb; CAM-30: 4.16 lb.
Agency Approvals:
CE.