Series
102/1102

Flanged Chamber Type Level Control
Pressure to 400 psig (28 bar), Temperature to 425°F (218°C), Hermetically Sealed Switches, Series 102 Minimum Specific Gravity: 0.60, Series 1102 Minimum Specific Gravity: 0.40

POPULAR MODELS
Model
Number
DescriptionPrice Lead
Time
 102-WT-7810-C-60 Flanged chamber type level control, SPDT snap switch. $680.25 Normally Stocked Add To Cart
*Prices are based in US currency and may change for international customers due to and not limited to customs brokerage fees, export packing and documentation, tariffs, duty and taxes.
MODEL CHART - SERIES 102/1102
EXAMPLE 102 WT 7810 10 C1 60 12 102-WT-7810-C1-60 Liquid Level Control with flanged chamber enclosure, SPDT snap action switch, fixed deadband, automatic reset, Operating pressure 400 psig (28 bar) at 425°F (218°C), side/bottom, side/side mounting standard with 1" NPT connections, minimum specfic gravity 0.60.  
1102 WT 7810 10 C1 40   Same as 102 Series except minimum specific gravity is 0.40.  
ENCLOSURES     

G

          General purpose, NEMA 1. UL
  WT           Water-tight, NEMA 4, 4X. UL
  E           Explosion-proof, Class I Groups B, C, D, Class II Groups E, F, G, NEMA 7, 9. UL
  EV           Explosion-proof, vapor proof, Class I Groups B, C, D, Class II Groups E, F, G, NEMA 7, 9. UL
CIRCUITS
(for electrical circuits see charts below)
    48XX         Single stage, mercury switch, see chart A or C below.  
    48XX XX       Two stage, mercury switch, see chart A or C below.  
    78XX         Single stage, snap switch, see chart B or D below.  
    78XX XX       Two stage, snap switch, see chart B or D below.  
    78XXHM         Hermetically sealed snap switch, see chart B below.  
    98XX         Single stage, high capacity DC snap switch, use heat fins (HF) if process temperature excced 350°F (177°C), do not exceed 450°F (232°C), see chart B or D below.  
    98XX XX       Two stage, high capacity DC snap switch, use heat fins (HF) if process temperature excced 350°F (177°C), do not exceed 450°F (232°C), see chart B or D below.  
CHAMBER CONSTRUCTION            C     Cast iron chamber, pressure rating 300 psig (22 bar) at 425°F (218°C). UL
        C1     Cast steel chamber, pressure rating 400 psig (28 bar) at 425°F (218°C). UL
        C216     Cast 316SS chamber, float and rod, armature 430SS, pressure rating 400 psig (28 bar) at 425°F (218°C). UL
          40   Minimum specific gravity 0.40.  
          60   Minimum specific gravity 0.60. UL
OPTIONS             12 Breather and drain for E type enclosure. Recommended for high humidity or outdoor service.  

CHARTS A & B - ELECTRICAL CIRCUITS AND RATINGS - SERIES 102
SWITCH TYPE
SWITCH ACTION
ELECTRICAL RATINGS IN AMPS
ORDERING CODE
 
   
AC
DC
SINGLE STAGE
TWO STAGE
 
   
120V
240V
440V
30V
125V
250V
 
LOWER
UPPER
 
CHART A
Mercury Contacts
SP-ST open on level FALL
10
5
3†
 
10
5
-4821
-4821
-21
UL
SP-ST open on level RISE
10
5
3†
 
10
5
-4820
-4820
-20
UL
SP-DT one switch
4
2
1†
 
4
2
-4810
-4810
-10
UL
SP-DT two switches E.I.*
10
5
3†
 
10
5
-4815
-4815
-15
UL
DP-ST two switches E.I.* open on level FALL
10
5
3†
 
10
5
-4813
-4813
-13
UL
DP-ST two switches E.I.* open on level RISE
10
5
3†
 
10
5
-4814
-4814
-14
UL
DP-DT two SP-DT switches
4
2
1†
 
4
2
-4806
-4806
-06
UL
CHART B
snap action contacts
SP-DT one switch
12
5
3†
 
0.5**
0.25**
-7810
-7810
-10
UL
DP-DT Two SP-DT switches
12
5
3†
 
0.5**
0.25**
-7806
-7806
-06
UL
SP-DT one hermetically sealed switch
5
5
 
5**
 
 
-7810HM
-7810HM
-10HM
 
DP-DT two hermetically sealed SP-DT switches
5
5
 
5**
 
 
-7806HM
-7806HM
-06HM
 
DP-DT two SP-DT switches
10
3
 
 
10‡
3‡
-9806
-06
 
 
SP-DT one switch
10
3
 
 
10‡
3‡
-9810
-10
 
 

†Available on special order, change 1st digit in ordering code from 4 to 5 or 7 to 8, i.e., -4820 becomes -5820, -7810 becomes -8810, etc.
‡10 amp inductive (polarized) at 125 VDC.
*Electrically Independent.
**Resistive.

CHARTS C & D - ELECTRICAL CIRCUITS AND RATINGS - SERIES 1102
SWITCH TYPE
SWITCH ACTION
ELECTRICAL RATINGS IN AMPS
ORDERING CODE
   
AC
DC
SINGLE STAGE
TWO STAGE
   
120V
240V
440V
30V
125V
250V
 
LOWER
UPPER
CHART C
Mercury Contacts
SP-ST open on level FALL
10
5
3†
 
10
5
-4821
-4821
-21
SP-ST open on level RISE
10
5
3†
 
10
5
-4820
-4820
-20
SP-DT one switch
4
2
1†
 
4
2
-4810
-4810
-10
SP-DT two switches E.I.*
10
5
3†
 
10
5
-4815
-4815
-15
DP-ST two switches E.I.* open on level FALL
10
5
3†
 
10
5
-4813
-4813
-13
DP-ST two switches E.I.* open on level RISE
10
5
3†
 
10
5
-4814
-4814
-14
DP-DT two SP-DT switches
4
2
1†
 
4
2
-4806
-4806
-06
CHART D
snap action contacts
SP-DT one switch
12
5
3†
 
0.5**
0.25**
-7810
-7810
-10
DP-DT Two SP-DT switches
12
5
3†
 
0.5**
0.25**
-7806
-7806
-06
SP-DT one hermetically sealed switch
5
5
 
5**
 
 
-7810HM
-7810HM
-10HM
DP-DT two hermetically sealed SP-DT switches
5
5
 
5**
 
 
-7806HM
-7806HM
-06HM
DP-DT two SP-DT switches
10
3
 
 
10‡
3‡
-9806
-06
 
SP-DT one switch
10
3
 
 
10‡
3‡
-9810
-10
 
†Available on special order, change 1st digit in ordering code from 4 to 5 or 7 to 8, i.e., -4820 becomes -5820, -7810 becomes -8810, etc.
‡10 amp inductive (polarized) at 125 VDC.
*Electrically Independent.
**Resistive.

Home Product Information Free Literature International Distribution What's New About Us Careers Contact Us
Terms & Conditions of Sale
Terms of Access
© Copyright 2005  Dwyer Instruments, Inc. All rights reserved.