| Home | Product Information | Free Literature | International Distribution | What's New | About Us | Careers | Contact Us | ||
|---|---|---|---|---|---|---|---|---|---|
|
|||||||||
|
|
|
|||||||||||||||||||||||
|
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Current/Voltage Calibrator -
Model CSG Ramp Function, Large Numeric LCD Display |
||||||||||||||||||||||||
|
Multi-Cal Benchtop Calibrator -
Model MC6 Interchangable Ranges, ±0.5% Accuracy, Datalogging Capability, NIST Tracable |
||||||||||||||||||||||||
|
Multi-Cal Pressure Calibrator -
Series MC Interchangable Ranges, ±0.5% Accuracy, Datalogging Capability, NIST Tracable |
||||||||||||||||||||||||
|
Smart Loop Calibrator -
Model LC21 Measures and Generates Milliamps, Auto-Stepping, Auto-Ramping |
||||||||||||||||||||||||
|
Thermocouple Calibrator -
Model CA10 Accepts Type K Thermocouples, High/Low Alarm, Selectable Resolution |
||||||||||||||||||||||||
|
Thermocouple Calibrator -
Model CA20 Accepts Type J Thermocouples, High/Low Alarm, Selectable Resolution |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Conductivity Tester -
Series EC Waterproof, ±1% FS Accuracy |
||||||||||||||||||||||||
|
SAFE-T-GROUND -
Model TR-7 Explosion-proof, Intrinsically Safe, Ground and Continuity Control |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Current Switch -
Series CS Universal Output, Solid or Split Core Case |
||||||||||||||||||||||||
|
Current Transformer -
Series CT40/50 4-20 mA or 0-5 VDC Output, Split Core Case |
||||||||||||||||||||||||
|
True RMS Current Transformer -
Series CT60/70 Field Selectable Range, Split Core Case |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Direct-Contact Speed Switch -
Series DSS Rugged Housing, Electronics and Mechanical Components in One Housing |
||||||||||||||||||||||||
|
Non-Contact Speed Switch -
Series NSS Compact Housing, Easy Installation |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Waterproof Pocket Size pH Tester -
Model WPH1 ±0.2 pH Accuracy, Push Button Claibration, O.1 pH Resolution |
||||||||||||||||||||||||
|
Pocket Sized pH Tester -
Model WPH2 ±0.1 pH Accuracy, Automatic Temperature Compensation, 3-pt Calibration |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Particle Monitor -
Series DPM Real-Time Leak Gauge, Adjustable Alarm Points |
Particulate Sensor -
Series PMS Reliable Operation, Minimal Maintenance |
Particulate Transmitter -
Series PMT 2-Wire Loop Powered |
||||||||||||||||||||||
|
Total Dissolved Solids (TDS) Tester -
Series TDS ±1% Accuracy, Automatic Temperature Compensation, Replaceable Sensor |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Proximity Sensor -
Series PS Capactive or Inductive, 3-Wire DC |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Analog Signal Generator -
Model ASG 0-10 VDC or 0-20 mA Signal, Bar Graph LED |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Digital Multimeter -
Model MM10 Measures AC/DC Voltage, DC Current and Resistance, Overload Protection |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Intrinsically Safe Relay -
Model SSR-15 SPST Switch Operation, 5 Amp |
||||||||||||||||||||||||
|
Solid State Relay -
Series SSR SPST Switch Operation, 5 or 10 Amp |
||||||||||||||||||||||||
|
|
||||||||||||||||||||||||
|
Calibration Pump -
Model A-396A Generates Pressures to 72 psig (bar) |
||||||||||||||||||||||||
|
Combustible Leak Detector -
Model CLD20 Adjustable Tick Rate, <1 Second Response, Audio/Visual Indication |
||||||||||||||||||||||||
|
Combustion Test Kit -
No. 1200 A Complete Kit for the Professional Heating Engineer |
||||||||||||||||||||||||
|
Galvanic Isolator -
Series MTL5041/5045 Intrinsically Safe Isolators for Hazardous Locations |
||||||||||||||||||||||||
|
Handheld
Carbon Monoxide Analyzer - Model
1205A-5 Range 0 to 2000 ppm CO, ±5% Accuracy |
||||||||||||||||||||||||
|
Handheld Flue Gas Analyzer -
Model 1207 11 Pre-Programmed Fuels, Built-in Calibration, Optional NOx Sensor |
||||||||||||||||||||||||
|
Hand Pump -
Model HP Generates Pressures up to 30 psi (2 bar) |
||||||||||||||||||||||||
|
Hydraulic Hand Pump -
Model HHP Pressures up to 10,000 psi (700 bar) |
||||||||||||||||||||||||
|
Pneumatic Hand Pump -
Model PHP Generates Pressures up to 600 psi (40 bar) |
||||||||||||||||||||||||
|
Pneumatic Hand Pump -
Series CHP Vacuum or Pressure, Ranges up to 100 psig |
||||||||||||||||||||||||
|
Refrigerant Leak Detector -
Model RLD1 Adustable Tick Rate, <1 Second Response, Audio/Visual Indication |
||||||||||||||||||||||||
|
Smoke Gage Kit -
No. 920 A Complete Kit for the Professional Heating Engineer |
||||||||||||||||||||||||
|
Control Transformer -
Model A-699 Power 4-wire Transmitters |
||||||||||||||||||||||||
|
Electronic Fan speed Control -
Model FC-1000 0-10 VDC Input, Selectable Hard Start |
||||||||||||||||||||||||
|
Indicating Annunciator -
Series AN14 Visible and Audible Alarms |
||||||||||||||||||||||||
|
Panel Meter/Power Supply -
Model A-701 Provides Digital Indication |
||||||||||||||||||||||||
|
Power Supply -
Model A-700 Economical and Reliable |
||||||||||||||||||||||||
|
Process Indicator and Alarm -
Series 1000 Operates 2-wire Transmitters |
||||||||||||||||||||||||
|
Proximity Switch Tester -
Model A-800 For 2, 3 or 4 Wire DC Switches |
||||||||||||||||||||||||
|
Zener Barrier -
Series MTL7706/7787 Intrinsically Safe Barriers for Hazardous Locations |
||||||||||||||||||||||||
| Home | Product Information | Free Literature | International Distribution | What's New | About Us | Careers | Contact Us |
| Terms & Conditions of Sale | |||||||
| Terms of Access | |||||||
| © Copyright 2005 Dwyer Instruments, Inc. All rights reserved. | |||||||