Series UFC Ultrasonic Flowmeter Set
Non-Invasive Pipe Flow Measurement, Easy Operation and Data Logging Option
No longer available.
For non-data logging version see Series UFB.
Specifications
- Service:
- Homogeneous liquids that do not contain more than 3% of air bubbles or particulate and capable of ultrasonic wave propagation.
- Inputs:
- TNC cable from sensors.
- Range:
- 0.33 to 33 ft/s (0.1 to 10 m/s) .
- Display:
- 240 x 64 pixel graphic display, high contrast black on white with backlight. Languages: English, French, German, Swedish, Italian, Spanish, Portuguese, Russian, Norwegian, and Dutch; 5" W x 1.3" H (5 x 33.02 mm).
- Accuracy:
- ±0.5 to ±2% of flow reading of flow rate > 0.03 ft/s (0.01 m/s) and pipe OD > 3.0 in (75 mm); ±3% of flow reading for flow rate > 0.03 ft/s (0.01 m/s) and pipe OD 0.5 to 3 in (13 to 75 mm); ±6% of flow reading for flow rate < 0.03 ft/s (0.01 m/s).
- Power Requirements:
- 86 to 264 VAC (50 to 60 Hz) or 24 VAC/VDC (1 A max.).
- Power Consumption:
- 10.5 W.
- Temperature Limits:
- Transducer: -4 to 275°F (-20 to 135°C); Controller: -4 to 122°F (-20 to 50°C).
- Outputs:
- Analog: 1 opto-isolated output: 4 to 20 mA, 0 to 16 mA or 0 to 20 mA (selectable); Error current: 0 to 26 mA (selectable); Load resistance: 620 O max; Alarm: 2 opto-isolated MOSFET NO relays, 48 V at 500 mA, maximum 200 Hz; Pulsed: 1 opto-isolated MOSFET relay, 48 V at 500 mA, 1 to 250 pps; Pulse width: 2 to 500 ms (selectable).
- Serial Communications:
- USB.
- Materials:
- Plastic ABS and aluminum.
- Repeatability:
- ±0.5% of measured value or 0.03 ft/s (0.01 m/s).
- Electrical Connections:
- Removeable screw in type terminal block.
- Mounting:
- Wall mounted using 3 type M4 screws.
- Turbidity:
- <3% by volume of particulate content.
- Permissible Air Content:
- <3% by volume.
- Response Time:
- <500 ms.
- Weight:
- Unit not including accessories: 2.80 lb (1.26 kg); Unit including accessories: 9.92 lb (4.5 kg).
- Agency Approvals:
- CE.
- ADDITIONAL SPECIFICATIONS
- Applicable Pipe Material:
- Carbon steel, SS, copper, UPVC/PVDF, concrete, mild steel, glass, brass.
- Applicable Pipe Lining:
- Rubber, glass, concrete, epoxy, steel, plastic, other.*
- Pipe Wall Thickness:
- 0.04 to 3" (1 to 75 mm).
- Pipe Lining Thickness:
- <1" (<25 mm).
- *Selectable option for special material with known propagation rate of the lining material.
Approvals
Drawings
Product Reviews
Only registered users can write reviews. Please Sign in or create an account