Series PBV Automated Ball Valve - Two-Way Plastic
Electric and Pneumatic Actuators
The Series PBV Plastic Automated Ball Valves are ideal for services in industrial, chemical, turf and irrigation, and pool and spa applications, as well as for use with potable water. The valve features shear-proof stem designed to prevent leakage in the event of damage, reinforced TFE seats and EPDM seals for longer life, and an all-plastic construction (PVC or CPVC) for heavyweight durability at a lightweight cost. Valves also come standard with field selectable NPT or socket process connections.
The PBV is an economical automated valve package with either an electric or pneumatic actuator. Electrically actuated models are weatherproof, NEMA 4, powered by standard 115 VAC supply, and are available in either two-position or proportional control. Two-position actuators use the 115 VAC input to drive each of the valve ports open or closed, while the modulating actuator accepts a 4 to 20 mA input for infinite valve positioning. Actuator features include thermal overload protection to withstand stall conditions, visual position indication and a permanently lubricated gear train.
The pneumatic double acting actuator uses an air supply to drive each of the actuator ports. Spring return pneumatic actuators use the air supply to drive the valve stem one direction, and internally loaded springs return the valve to its original position. Also available is the SV3 solenoid valve to electrically switch the supply pressure between the air supply ports. Actuators are constructed of anodized aluminum and are epoxy coated for years of corrosion free service.
Product Applications
- Gas or liquid flow control
Models & Ordering
Specifications
- Service:
- Compatible liquids or gases.
- Body:
- 2-way.
- Line Size:
- 1/2" to 4".
- End Connections:
- Female NPT or socket (for 1/2" through 2"); socket only (for 2- 1/2" through 4").
- Pressure Limit:
- 1/2" to 2": 232 psi (16.0 bar) @ 73°F (23°C); 2-1/2" to 4": 150 psi (10.3 bar) @ 73°F (23°C) WOG. Vacuum: 29" Hg.
- Wetted Materials:
- Body & End Connections: PVC or CPVC; Ball & Stem: PVC or CPVC; Seat: TFE; Stem Seal: EPDM.
- Temperature Limit:
- 32 to 140°F (0 to 60°C).
- Other Materials:
- Stem Bearing: Polypropylene (1-1/4" and up).
- ACTUATORS
- Electric
- Power Requirements:
- 120 VAC, 50/60 Hz, single phase. Optional 220 VAC, 24 VAC, 12 VDC, and 24 VDC.
- Power Consumption (Locked Rotor Current):
- Two Position: 1/2" to 1-1/2": 0.55A; 2" to 4": 0.75A. Modulating: 1/2" to 2": 0.75A; 2-1/2": 1.1A; 3" to 4": 0.75A.
- Cycle Time (per 90°):
- Two Position: 1/2" to 1-1/2": 2.5 sec.; 2" to 2-1/2": 5 sec.; 3" to 4": 15 sec. Modulating: 1/2" to 2-1/2": 5 sec.; 3" to 4": 15 sec.
- Duty Cycle:
- Two Position: 1/2" to 1-1/2": 75%; 2" to 4": 25%. Modulating: 75%.
- Enclosure Rating:
- NEMA 4. Optional NEMA 7 (Class 1, Div. II, Groups A, B, C, D).
- Housing Material:
- Aluminum with thermal bonding polyester powder finish.
- Temperature Limit:
- 0 to 150°F (-18 to 65°C).
- Conduit Connection:
- 1/2" female NPT.
- Modulating Input:
- 4 to 20 mA.
- Standard Features:
- Manual override and visual position indicator except modulating units.
- Pneumatic "DA" and "SR" Series
- Type:
- DA series is double acting and SR series is spring return (rack and pinion).
- Normal Supply Pressure:
- 80 psi (5.5 bar).
- Maximum Supply Pressure:
- 120 psig (8 bar).
- Air Connections:
- DA1 to 5 and SR2 to 5: 1/8" female NPT; all others: 1/4" female NPT.
- Air Consumption (per stroke):
- DA1: 2.32 cu. in.; DA2: 9.34 cu. in.; DA3: 17.21 cu. in.; DA4: 20.5 cu. in.; SR2: 9.34 cu. in.; SR3: 17.21 cu. in.; SR6: 54.34 cu. in.; SR7: 85.43 cu. in.
- Cycle Time (per 90°):
- DA1: .03 sec.; DA2: .04 sec.; DA3: .08 sec.; DA4: .12 sec.; SR2: .09 sec.; SR3: .14 sec.; SR6: .46 sec.; SR7: .83 sec.
- Housing Material:
- Anodized aluminum body and epoxy coated aluminum end caps.
- Temperature Limit:
- -4 to 180°F (-20 to 82°C).
- Accessory Mounting:
- NAMUR standard.
- Standard Features:
- Visual position indicator.
Features
- Shear proof stem
- All plastic construction
Options
- Explosion-proof Electric Actuator - Add suffix "EX" to the model number.
- Optional Electric Actuator Supply Voltages - Contact factory for model number change - 24 VAC, 220 VAC, 24 VDC or 12 VDC.
- Solenoid Valve -- See Model SV3.
Model Chart
EXAMPLE | PBV | C | U11 | 02 | EX | Series PBVCU1102-EX 1/2" Two-Way Plastic Automated Ball Valve, with electric two position 120 VAC size 100 explosion-proof actuator. |
SERIES | PBV | Two-Way Plastic Automated Ball Valve | ||||
MATERIAL | C P |
CPVC PVC |
||||
ACTUATOR | DA1 DA2 DA3 DA4 SR2 SR3 SR6 SR7 U11 U12 U13 U15 U21 U22 U23 U25 U31 U32 U33 U35 U41 U42 U43 U45 U51 U52 U53 U55 V12 V13 V15 V22 V23 V25 V32 V33 V35 V42 V43 V45 V52 V53 V55 |
Direct Acting Rack & Pinion Actuator Size 32 Direct Acting Rack & Pinion Actuator Size 52 Direct Acting Rack & Pinion Actuator Size 63 Direct Acting Rack & Pinion Actuator Size 75 Spring Return Rack & Pinion Actuator Size 52 Spring Return Rack & Pinion Actuator Size 63 Spring Return Rack & Pinion Actuator Size 100 Spring Return Rack & Pinion Actuator Size 115 Electric Two Position 120 VAC Size 100 Electric Two Position 120 VAC Size 200 Electric Two Position 120 VAC Size 300 Electric Two Position 120 VAC Size 675 Electric Two Position 220 VAC Size 100 Electric Two Position 220 VAC Size 200 Electric Two Position 220 VAC Size 300 Electric Two Position 220 VAC Size 675 Electric Two Position 24 VAC Size 100 Electric Two Position 24 VAC Size 200 Electric Two Position 24 VAC Size 300 Electric Two Position 24 VAC Size 675 Electric Two Position 24 VDC Size 100 Electric Two Position 24 VDC Size 200 Electric Two Position 24 VDC Size 300 Electric Two Position 24 VDC Size 675 Electric Two Position 12 VDC Size 100 Electric Two Position 12 VDC Size 200 Electric Two Position 12 VDC Size 300 Electric Two Position 12 VDC Size 675 Electric Modulating 120 VAC Size 200 Electric Modulating 120 VAC Size 300 Electric Modulating 120 VAC Size 675 Electric Modulating 220 VAC Size 200 Electric Modulating 220 VAC Size 300 Electric Modulating 220 VAC Size 675 Electric Modulating 24 VAC Size 200 Electric Modulating 24 VAC Size 300 Electric Modulating 24 VAC Size 675 Electric Modulating 24 VDC Size 200 Electric Modulating 24 VDC Size 300 Electric Modulating 24 VDC Size 675 Electric Modulating 12 VDC Size 200 Electric Modulating 12 VDC Size 300 Electric Modulating 12 VDC Size 675 |
||||
CONNECTION SIZE | 02 03 04 05 06 07 08 09 10 |
1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 2-1/2" 3" 4" |
||||
OPTIONS | EX FO SV SV-A SV-B SV-C SV-D 2S |
Explosion-proof Electric Actuator Fail Open Solenoid Valve, 120 VAC Solenoid Valve, 12 VDC Solenoid Valve. 24 VDC Solenoid Valve, 240 VAC Solenoid Valve, 24 VAC Two Internal Auxiliary Limit Switches |
PVC MODELS
Size
|
Cv
|
Double Acting
Pneumatic |
Spring Return
Pneumatic |
Two Position
Electric |
Modulating
Electric |
1/2"
|
25
|
PBVPDA102
|
PBVPSR202
|
PBVPU1102
|
PBVPV1202
|
3/4"
|
51
|
PBVPDA103
|
PBVPSR203
|
PBVPU1103
|
PBVPV1203
|
1"
|
97
|
PBVPDA104
|
PBVPSR204
|
PBVPU1104
|
PBVPV1204
|
1-1/4"
|
204
|
PBVPDA105
|
PBVPSR205
|
PBVPU1105
|
PBVPV1205
|
1-1/2"
|
285
|
PBVPDA206
|
PBVPSR306
|
PBVPU1106
|
PBVPV1206
|
2"
|
540
|
PBVPDA207
|
PBVPSR307
|
PBVPU1207
|
PBVPV1207
|
2-1/2"
|
712
|
PBVPDA308
|
PBVPSR608
|
PBVPU1308
|
PBVPV1308
|
3"
|
1294
|
PBVPDA309
|
PBVPSR609
|
PBVPU1509
|
PBVPV1509
|
4"
|
2629
|
PBVPDA410
|
PBVPSR710
|
PBVPU1510
|
PBVPV1510
|
CPVC MODELS
Size
|
Cv
|
Double Acting
Pneumatic |
Spring Return
Pneumatic |
Two Position
Electric |
Modulating
Electric |
1/2"
|
25
|
PBVCDA102
|
PBVCSR202
|
PBVCU1102
|
PBVCV1202
|
3/4"
|
51
|
PBVCDA103
|
PBVCSR203
|
PBVCU1103
|
PBVCV1203
|
1"
|
97
|
PBVCDA104
|
PBVCSR204
|
PBVCU1104
|
PBVCV1204
|
1-1/4"
|
204
|
PBVCDA105
|
PBVCSR205
|
PBVCU1105
|
PBVCV1205
|
1-1/2"
|
285
|
PBVCDA206
|
PBVCSR306
|
PBVCU1106
|
PBVCV1206
|
2"
|
540
|
PBVCDA207
|
PBVCSR307
|
PBVCU1207
|
PBVCV1207
|
2-1/2"
|
712
|
PBVCDA308
|
PBVCSR608
|
PBVCU1308
|
PBVCV1308
|
3"
|
1294
|
PBVCDA309
|
PBVCSR609
|
PBVCU1509
|
PBVCV1509
|
4"
|
2629
|
PBVCDA410
|
PBVCSR710
|
PBVCU1510
|
PBVCV1510
|
NOTE: All spring return actuators are factory standard as spring (fail) close. For spring (fail) open valves, add suffix "-FO" to the model number.